Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG

Place of Origin China
Brand Name Zecen
Certification CE, ISO13485
Model Number Thyroid disease test kit
Minimum Order Quantity 1
Price Negotiable
Packaging Details Wooden case or carton package
Delivery Time 10 workdays
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 5000 Set/Sets per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Applications For Thyroid Diseases Tested Parameter TSH, TT3, TT4, FT3, FT4, TFAb, TPOAb, TRAb, TG
Analysis Mode CLIA Storage 2-8℃
Package Specification 50T/BOX, 100T/BOX,24T/BOX Quanlity Guarantee Period 12 Months
High Light

Thyroid Disease IVD Products

,

CE IVD Products

,

TSH In Vitro Diagnostic Reagents

Leave a Message
Product Description

 

 

Thyroid Disease Test Kit for Chemiluminescence Immunoassay Analyzer

TSH, TT3, TT4, FT3, FT4, TFAb, TPOAb, TRAb, TG

 

 


The seven items of thyroid function specifically refer to three-point thyroxine, free thyroxine, and thyroid-stimulating hormone. The seven items of thyroid function are important clinical indicators. Through these items, it can be judged whether the individual indicators are within the normal range. If all indicators are normal, certain diseases can be excluded. 

 

1.T3 triiodothyronine (reference value: 1.303.10nmol/L)

2. T4 thyroxine (reference value: 66.00181.00nmol/L)

3.FT3 free triiodothyronine (reference value: 3.106.80pmol/L)

4.FT4 free thyroxine (reference value: 12.0022.00pmol/L)

5.TSH thyroid stimulating hormone (reference value: 0.2704.200mIU/L)

6. TGAb anti-thyroglobulin antibody (reference value: 0.00115.00kIU/L)

7. TPOAb anti-thyroid peroxidase antibody (reference value: 0.0034.00kIU/L) is for reference only, and the specific reference value of the local hospital laboratory test sheet shall prevail.

 

 

The seven items of thyroid function specifically refer to three-point thyroxine, free thyroxine, and thyroid-stimulating hormone. The seven items of thyroid function are important clinical indicators. Through these items, individual indicators can be judged
The seven items of Jia Gong include:

 

1, three-point thyrogenine, its clinical significance, increased value, seen in hyperthyroidism, three-point thyrogenine type hyperthyroidism, decreased in hypothyroidism, the normal reference value is 4-10 mmol per liter.

2. Free thyroxine, its clinical significance, increased, thyrotoxicosis, sudden hyperthyroidism, painless thyroiditis with hyperthyroidism, subacute thyroiditis with hyperthyroidism, chronic thyroiditis with hyperthyroidism, decreased suggestive hypothyroidism, pituitary Sexual or painless subacute thyroiditis, hypoalbuminemia, the normal reference value is 10-31 mmol per liter.

3. Thyroid-stimulating hormone, its normal value is 2-10 mmol per liter, the increase is seen in primary hyperthyroidism, Hashimoto's disease with hypothyroidism, subacute thyroiditis recovery period, and the decrease indicates pituitary thyroid function Hypothyroidism, for hyperthyroidism caused by TSH tumors.

4, anti-thyroid catalase autoantibodies.

5, the total triiodothyronine amino acid, its decrease suggests hypothyroidism, increased. TT3 is the most sensitive indicator for the diagnosis of hyperthyroidism.

6, total thyroid hormones, increased suggest hyperthyroidism, acute thyroiditis, acute hepatitis, obesity; decreased suggest hypothyroidism, hypopituitarism.

7, anti-thyrotropin receptor resistance, positive can be seen in autoimmune hyperthyroidism, neonatal transient hyperthyroidism, thyroiditis with hypothyroidism.

 

 

 

 

 

product composition Two points: LH
Six points: ABCDEF
Testing method 1. Treat the calibrator as the sample to be tested, and place it in the sample loading area of the instrument after mixing. Note that when mixing Avoid air bubbles.
2. During the detection, the system detects the luminescence value (RLU value) of each calibration point, and calculates the luminescence value according to the nominal concentration and luminescence value.
The calibration curve is automatically fitted by the instrument. In order to ensure the reliability of the calibration curve, the determination of the calibrator should be
Make a double.
3. The generated calibration curve can be used for 28 days, but it should be re-calibrated after the following conditions:
① Change of batch number of supporting testing reagents;
Change of batch number of luminescent substrate
②The measured value of the quality control product is not within the scope of quality control or the test results are inconsistent with the clinical situation;
③System for major repairs or maintenance.
Interpretation of test results 1. For reasons such as methodology or antibody specificity, the same sample was tested using reagents from different manufacturers.
Testing with different reagents may give different test results, therefore, the results obtained by testing with different reagents should not be directly
They are compared with each other in order to avoid false medical interpretations.
2. The quality control product can be used as a reference for the reliability of the current experimental results, and its measured value should be within the
within the range allowed by the quality control sheet. Test results should be based on reference value ranges and other clinical factors and results
Comprehensive judgment, when the test result is close to the upper limit or lower limit of the reference value range, it can be considered
samples for confirmation testing.
Storage and expiration date

Stored at 2-8°C, the product is valid for 12 months. Reagents should be used within 1 month after opening, and stored at 2-8°C away from direct sunlight.

 

 

 

 

 


 

 

 

 

 

Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG 0

Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG 1

Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG 2Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG 3

Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG 4

Thyroid Disease Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer TSH TT3 TT4 FT3 FT4 TFAb TPOAb TRAb TG 5